ES Series

Hybrid Inverter

The Goodwe ES series bi-directional energy storage inverter can be used for both on-grid and off-grid PV systems, with the ability to control the flow of energy intelligently.

During the day, the PV array generates electricity which can be provided either to the loads, fed into the grid or charge the battery, depending on the economics and set-up.

The electricity stored can be released when the loads require it during the night, including inductive loads such as air conditioners or refrigerators.

Additionally, the power grid can also charge the storage devices via the inverter. An all-round intelligent system for maximum energy flexibility.

Charge controller and inverter integrated.

Export control (Zero export)

UPS function with 10 ms automatic switchove

Maximum charge and discharge up to 100A

IP65 dustproof and waterproof

Fanless design, long lifespan

ModelMax. Charging Current (A)*1Max. Discharging Current (A)*1Max. DC Input Power (W)Nominal Apparent Power Output to Utility Grid (VA)Max. Apparent Power Output to Utility Grid (VA)*4Max. Apparent Power from Utility Grid(VA)
GW3648D-ES75754600368036807360
GW5048D-ES1001006500460051009200
ModelMax. AC Current Output to Utility Grid (A) [On-grid]Max. AC Current From Utility Grid (A)[On-grid]Max. Output Apparent Power (VA)[Back-up]Peak Output Apparent Power (VA)*6[Back-up]Max. Output Current (A)[Back-up]Weight (kg)
GW3648D-ES163236805520,10sec1628
GW5048D-ES24.5*54046006900,10sec2030
Battery Input Data
Battery TypeLi-Ion or Lead-acid*1
Nominal Battery Voltage (V)48
Max. Charging Voltage (V)≤60 (Configurable)
Battery Capacity (Ah)*250~2000
Charging Strategy for Li-Ion BatterySelf-adaption to BMS
PV String Input Data
Max. DC Input Voltage (V)580
MPPT Range (V)125~550
Start-up Voltage (V)*3150
MPPT Range for Full Load (V)170~500
Nominal DC Input Voltage (V)360
Max. Input Current (A)11/11
Max. Short Current (A)13.8/13.8
No. of MPP Trackers2
No. of Strings per MPP Tracker1
AC Output Data (On-grid)
Nominal Output Voltage (V)230
Nominal Output Freqency (Hz)50/60
Output Power Factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output)<3%
AC Output Data (Back-up)
Nominal Output Voltage (V)230 (±2%)
Nominal Output Freqency (Hz)50/60 (±0.2%)
Output THDv (@Linear Load)<3%
Efficiency
Max. Efficiency97.6%
Max. Battery to Load Efficiency94.0%
Euro Efficiency97.0%
Protection
Anti-islanding ProtectionIntegrated
PV String Input Reverse Polarity ProtectionIntegrated
Insulation Resistor DetectionIntegrated
Residual Current Monitoring UnitIntegrated
Output Over Current ProtectionIntegrated
Output Short ProtectionIntegrated
Output Over Voltage ProtectionIntegrated
General Data
Operating Temperature Range (°C)-25~60
Relative Humidity0~95%
Operating Altitude (m)≤ 4000
CoolingNatural Convection
Noise (dB)<25
User InterfaceLED & APP
Communication with BMS*7RS485; CAN
Communication with MeterRS485
Communicaiton with PortalWi-Fi
Size (Width*Height*Depth mm)516*440*184
MountingWall Bracket
Protection DegreeIP65
Standby Self Consumption (W)<13
TopologyHigh Frequency Isolation
Certifications & Standards
Grid RegulationVDE-AR-N 4105, VDE0126-1-1, AS4777.2, G83/2, CEI 0-21, NRS 097-2-1, EN50438
Safety RegulationIEC/EN62109-1&2, IEC62040-1
EMCEN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN 61000-4-16, EN 61000-4-18, EN 61000-4-29

*1 : Lead-acid battery use refers to Approved Battery Options Statement.
The actual charge and discharge current also depends on the battery.
*2 : Under off-grid mode, then battery capacity should be more than 100Ah.
*3 : When there is no battery connected, inverter starts feeding in only if string voltage is higher than 200V.

*4 : 4600 for VDE 0126-1-1 &VDE-AR-N4105, 4950 for AS4777.2(GW5048D-ES); 4050 for CEI0-21(GW3648D-ES).
*5 : 21.7A for AS4777.2
*6 : Can be reached only if PV and battery power is enough.
*7 : The standard configuration is CAN.